PHOTOSTABILITY CHAMBERS
 
 
  • ICH GUIDELINES (ICH Q1B).

  • For confirmatory studies, samples should be exposed to light providing an overall illumination of not less than 1.2 million Lux hours and an integrated near ultraviolet energy of not less than 200 watt hours/square meter to allow direct comparisons to be made between the drug substance and drug product.
CONSTRUCTION :

Double walled interior made of stainless steel. Exterior of mild finished in powder coating paint (optional stainless steel). Glass-wool/PUF insulation between both the wall is provided. Full-length inner glass door and outside metal door with magnetic gasket and lock. Forced air circulation for uniform temperature. One stainless steel, perforated tray is provided. The tray can be placed at various heights to accommodate the change in sample height. The purpose of doing so is to vary the exposure intensity to reduce the test duration. PU wheels for easy movability. In case of model Photostability Chamber With Humidity. Humidity is by steam injection and Humidity is directly displayed in % RH measured by capacitance type Electronic Humidity Sensor.

ILLUMINATION

Chamber is illuminated using 4nos of flourescent tube light to produce visible light (measure in lux). A one no. Near UV light of wavelength 365nm (measured in watt/sq. Meter) are fitted on topside of the chamber.

 
INTELLIGENT CONTROL SYSTEM :

The controlling system having is PLC Base and PC communication on Ethernet and data acquisition system complying with 21 CFR Part 11.

SENESOR :

Temperature and Humidity transmitter 4-20mA used for measurement. Temperature in degree Celsius and Humidity in %RH with 0.1°C and 0.1%RH resolution.

COOLING SYSTEM :

Hermetically sealed compressor couple with evaporation coil and fan cooled condenser, assembled in easy serviceable tray at bottom provides cooling below ambient temperature. Cooling in the chamber in necessary as the light source also generates excessive heat, which results in burning of samples without cooling.

ALARMS :

Audio and visual alarms are generated for temperature variation, utility failure.

SAFETY :

A Safety thermostat to switch off the tube lights if temperature overshoots. Door switch to switch off the UV light when door is opened.

STANDBY SENSOR :

When controlling sensor fails it automaticallyswitch over to standby sensor.


The unit works on 230 Volts AC and 50Hz mains supply.
 
SELECTION GUIDE FOR PHOTOSTABILITY CHAMBER :

Temperature Range : 10°C to 40°C Accuracy : ± 0.5°C
Temperature Uniformity : ±1°C

Models
Capacity
Inner Chamber
Dimension
External
Dimension
Exterior M.S.
Exterior S.S.
Cuft.
Liters
H x W x D (mm)
H x W x D (mm)
NEC-103RSP
NEC-103RSPS
3
90
450 x 470 x 450
1200 x 600 x 900

SELECTION GUIDE FOR PHOTOSTABILITY CHAMBER WITH HUMIDITY :

Temperature Range : 10°C to 40°C Accuracy : ± 0.2°C
Humidity Range : 40% RH to 80% RH Accuracy : ±2% RH
Temperature Uniformity : ±1°C Humidity Uniformity : ± 3% RH

Models
Capacity
Inner Chamber
Dimension
External
Dimension
Exterior M.S.
Exterior S.S.
Cuft.
Liters
H x W x D (mm)
H x W x D (mm)
NEC-203RSP
NEC-203RSPS
3
90
450 x 470 x 450
1200 x 600 x 900


* N.B. CUSTOM BUILD CHMABERS ALSO AVAILABLE.
 
OPTIONALS :

  • Stand by Cooling System (Auto Switch Over). The whole cooling system can be provided as standby. The stand by system comes in operational automatically with alarm when problem with regular cooling system is detected.

  • Common Software

  • Temperature Scanner

  • Mobile Alert System

 

ETHERNET COMMUNICATION PLC BASED INTELLIGENT CONTROL SYSTEM
    ................................................
  

STANDARD HARDWARE AVAILABLE GLOBALLY
    ................................................
 
  

REMOTE MONITORING
 ................................................
  

 ALARMS & REMOTE SMS
 ................................................

   more features - functions - flexibilty


 